Parallel termination will work with any number of loads. Figure 1 below illustrates the series termination method.
Proper Termination Of High Speed Digital Signals Marvin

Rs 485 Cable Specification Guide Maxim Integrated

Bus Termination For Rs 485
The most basic termination networks which are known as standard termination or parallel termination networks consist of a single resistor figure 2.

Parallel termination resistor value. Termination and series termination. Value such that r l r t z 0. The code below is the user mode version.
If r l is large then r t z 0. Youll need to make sure that the driver is compiled into your kernel or compiled as a module then loaded. Figure 2 below depicts parallel termination.
It accesses the parallel port via the ppdev driver. Standard termination network for standard termination you would match the termination resistor value with the differential mode characteristic impedance of the cabling on both ends of the network. Parallel termination will work with any number of loads.
The value of the resistor is equal to the characteristic impedance of the line itself commonly referred to as zo. A closely related strategy is a thevenin termination where a pair of resistors. The first command below can be used to check if the module is loaded the second will load it.
Add parallel resistor at receiver. Parallel termination dissipates the most power at low clock rates but only requires one resistor. In most designs a value of r 25 w to 30w is recommended.
The next three termination methods eliminate reflection at load end. Load termination involves placing a resistor in parallel between signal and ground with value such that the parallel combination of the termination resistor and load resistance equals the characteristic impedance of the transmission line. Series termination the other three termination techniques provide clean clock signals at the load.
If you add another resistor in parallel with the first one you have essentially opened up a new channel through which more current can flow. When we use parallel termination we place a terminating resistor at the end of the transmission line. No matter how large the second resistor is the total current flowing from the power supply will be at least slightly higher than the current through the single resistor.
Parallel termination if you place a single resistor from the trace to ground or vcc you get whats called a parallel termination. Parallel termination is easy to implement because the value of the resistor is easy to obtain you only need one extra component and it perfrorms well with distributed loads.

On Chip Resistance Value Compensation Technique For

Biasing An Rs485 Nw Pdf Document

Suppression Method Of Signal Reflection In High Speed Pcb

Notes On Wide Band Multi Wire Folded Dipoles

Voltage Conversion

An Overview Of Transmission Lines In Electronic Systems In

Practical Tips Can Bus Kmp Drivetrain Solutions

Notes On Wide Band Multi Wire Folded Dipoles

Solved Write A Program That Calculates The Equivalent Res

Reducing Ringing Or Reflections By Controlling Impedance Lines

Flexray E Flexray Bus

Rw Koa Speer Electronics